Bioengineering / drug testing
Microfluidic lab-on-a-chip and organ-chips
Organ-chips are small devices where living human cells line tiny perfused channels, so they behave more like real tissue than a flat dish. NIH funds them so scientists can assess biomarkers, efficacy and toxicity of drugs before clinical trials. In orbit, astronauts show signs of accelerated ageing, and human tissue on chips has shown related changes, for example weaker, arrhythmic engineered heart tissue after a month on the ISS. Microgravity can therefore act as a stressor that brings out tissue damage and drug effects. Chips need only microlitres of fluid and simple pumps, which suits an automated, uncrewed lab.
Who it is for
- Pharmaceutical and biotech companies testing drug toxicity on human kidney, liver, heart or gut tissue
- Organ-chip and microphysiological-system makers that want flight data
- Academic groups funded under programmes like NIH NCATS and ISS National Lab Tissue Chips in Space
- Space agencies studying astronaut health risks (heart, kidney, bone, immune) and countermeasures
- Contract research organisations that offer in-vitro toxicology services
What earlier flights found
| Year | Mission | What flew | What it found |
|---|---|---|---|
| 2006 | GeneSat-1 (NASA Ames)free-flyer cubesat | Microbes, to study gene expression in spaceflight | An early NASA Ames biological cubesat. A 2019 NASA review groups it with PharmaSat, EcAMSat and BioSentinel as heritage for autonomous biology on small free-flyers.6 |
| 2009 | PharmaSat (NASA Ames)free-flyer nanosatellite (5.1 kg) | Yeast (S. cerevisiae) in 48 microfluidic wells dosed with several concentrations of the antifungal voriconazole, read by a 3-colour optical absorbance system at each well, inside a sealed 1.2 L payload vessel | The team got in-orbit yeast growth curves at several drug doses and ran matched ground controls. This is the closest heritage for automated drug dosing and optical readout in microfluidic wells on a free-flyer.46 |
| 2017 | EcAMSat (NASA Ames / Stanford)free-flyer 6U cubesat (11 kg) | Uropathogenic E. coli (wild type and a strain lacking the rpoS gene) grown in a fluidic card and then exposed to three doses of gentamicin | Microgravity did not change growth rates. Both strains had slower metabolism in flight and were more susceptible to gentamicin, not more resistant. The rpoS-lacking strain was 34-37% less metabolically active than wild type on the ground and in flight. A ground test showed that multi-week storage in the payload hardware stressed the cells.56 |
| 2022 | BioSentinel (NASA Ames), on Artemis Ideep-space cubesat | Yeast housed in microfluidic cards, plus a radiation detector, to study the response to deep-space radiation | Four two-week experiments ran, but no yeast grew. NASA traced this to the yeast expiring during long storage before launch, not to radiation. The lesson is that biology must be loaded late and launch slips must be limited.7 |
| 2019 | Tissue Chips in Space, kidney proximal tubule chip (Univ. of Washington), SpaceX CRS-17ISS (BioServe perfusion platform, sealed, three Nortis Triplex chips per unit) | Human kidney proximal tubule cells from four donors in perfused 3-D chips. After 6 days of acclimation in orbit they got 2 days of 2% human serum, vitamin D, or plain medium. The chips were then fixed in orbit with RNAlater or formalin, and vitamin D effluent was frozen below -80 C on the ISS. | Microgravity did not change how the cells processed vitamin D, and it caused no unique response to serum. The authors say these pathways are not significantly altered by short-term exposure and call for study of longer exposure. Mold contamination made about a third of the flight samples unusable.12 |
| 2020 | Tissue Chips in Space, engineered heart tissue (Johns Hopkins / Univ. of Washington), SpaceX CRS-20ISS (automated heart-on-a-chip chambers in sealed habitats inside an ISS incubator at 37 C and 5% CO2) | Engineered heart tissues made from human iPSC-derived heart muscle cells, handed over live 2 days before launch and kept in orbit for about 30 days. Contraction was read in real time by magnets in flexible posts and magnetic sensors. Some tissues were fixed in orbit (PFA, stored at 4 C) or put in RNAlater (stored at -80 C). | Flight tissues had significantly weaker twitch forces and more arrhythmias, plus sarcomere disruption and mitochondrial damage. Genes linked to heart failure, metabolic disorders, oxidative stress and inflammation went up. Beat irregularity returned to normal after return to Earth; sarcomere changes did not.13 |
How LELP-1 runs it
Sample. Four to six human organ-chips supplied by the customer. Reference case: a kidney proximal tubule chip made with primary human tubule cells, with treated and vehicle chips side by side. The same layout works for liver, gut or heart chips. Container. Optically clear organ-chips on a fluidic manifold inside the BSL-2 triple-contained large bay, with a micro-pump per chip, bubble traps, valved reservoirs (medium, drug, fixative, RNA-stabilising reagent) and a cooled effluent-collection carousel. Launch. Live, mature tissue under continuous perfusion at 37 C (finished organ-chips are not launched frozen; the ISS heart tissues were handed over live 2 days before launch). The bay is loaded late and stays powered through launch. Light and gas. No light needed except brief imaging LEDs. HEPES-buffered medium with no CO2 (the ISS heart study used 5% CO2, which LELP-1 cannot supply). Oxygen comes from gas-permeable chip walls and tubing exposed to the sealed bay air.
- day -4
Ground: customer seeds the chips and perfuses them until the tissue forms. Chips that fail barrier or imaging checks are rejected. Sterile assembly and leak checks, because nobody can remove a contaminated chip in orbit.
- day -1
Late load: chips, filled reservoirs and the empty effluent carousel go into the large bay. The bay is sealed, held at 37 C and kept on power. The ground-control set is loaded the same way.
- day 0
Launch. Pumps keep a low continuous flow and the bay holds 37 C through ascent. The robotic arm stays parked.
- day 1
First in-orbit health check: brightfield image of every chip, check of flow and pressure for bubbles or blockage, first effluent fraction collected at 4 C.
- day 2
Days 2-6: acclimation under perfusion (the ISS kidney study used 6 days). One brightfield and fluorescence image set per day. One effluent fraction per chip every 24 h into the 4 C carousel.
- day 7
Dosing: the valves switch half the chips to medium containing the drug and half to vehicle medium. Imaging every 6 h.
- day 8
Effluent fractions every 12 h for injury and inflammation markers. Image sets continue.
- day 9
End point after 2 days of dosing: half the chips are flushed with an RNAlater-type RNA-stabilising reagent and half are fixed with 4% paraformaldehyde. Lines are sealed and the bay drops to 4 C.
- day 10
Bay held at 4 C through deorbit, re-entry and splashdown. Cassette goes to the customer's courier about 20 min after splashdown.
The payload module, in CAD
Every item in the module sheet, drawn and packed into the large bay deck by deck. The back face mates with the bay: blind-mate connector, and a cold wall against the bay's thermoelectric block. The front face carries Dexter-L's grapple fixture, and the fluid lines run down a channel just behind it. What you load before launch is marked blue in the configurator's payload guide.
CAD generated by cad/build_modules.py (CadQuery, OpenCascade kernel) from the catalog's module items: concept geometry, not a released design. Standard parts keep their real formats; the rest are sized from their catalog mass. The front panel and grapple fixture are left off in the 3-D view and are in the STEP.
Checks
| Fits the large bay | FITS | 313 x 191 x 365 mm envelope; 91 mm of height to spare |
| Mass | AS CATALOG | 5.80 kg in the parts, 5.80 kg in the catalog |
| Parts' boxes | 36 % of the 21.1 L inside | |
| Housing | THIN | 0.30 kg of structure and containment: a 0.14 mm aluminium skin |
| Centre of mass | -5 mm across and -9 mm front to back (+ is toward the front) from the middle, 97 mm up | |
| Lines | 8 fluid lines and 3 harness runs, routed in the channel behind the front panel |
Inside, top to bottom
- Top deck fluid pack
- Experiment deck imaging stack: inverted microscope, XY stage, sample
- Floor deck effluent carousel on a Peltier stage; controller and data storage; 4 micro-pumps, 4 valves on a manifold; bubble traps and inline sensors
- The XY stage travels 96.5 x 57.9 mm, so every one of the 24 wells reaches the objective; with the stage the imaging stack is 232 x 151 mm, which sets the module's depth budget.
- Reagent volumes the catalog does not state are split evenly from 75 % of the reservoir item's mass.
- Fluid pack: 5 reagent bags in 2 layers (210 x 101 x 46 mm), every port on a front edge.
- The catalog gives 0.30 kg for structure and containment; as an aluminium box that is a 0.14 mm skin on 0.09 kg of posts and shelves. Thin: the bay rails have to carry the launch loads, or the module needs more structure mass.
- The grapple fixture stands 26 mm proud of the front panel, into the bay opening; everything else is inside the bay envelope.
Components (6) and how each catalog item was drawn
| Component | Deck | kg | Box mm |
|---|---|---|---|
| effluent carousel on a Peltier stage | Floor deck | 0.70 | 90 x 90 x 47 |
| controller and data storage | Floor deck | 0.40 | 140 x 101 x 28 |
| 4 micro-pumps, 4 valves on a manifold | Floor deck | 1.20 | 50 x 146 x 38 |
| bubble traps and inline sensors | Floor deck | 0.30 | 80 x 30 x 31 |
| imaging stack: inverted microscope, XY stage, sample | Experiment deck | 2.00 | 232 x 151 x 156 |
| fluid pack | Top deck | 0.80 | 210 x 109 x 45 |
| Catalog item | kg | Drawn as |
|---|---|---|
| 4-6 organ-chips with holders and fluidic manifold | 0.60 | chips |
| Micro-pump array (one per chip) and pinch or rotary valves | 1.20 | pumps |
| Filled reservoirs: medium, drug, vehicle, fixative, RNA-stabilising reagent | 0.80 | bags |
| Effluent-collection carousel with its own small Peltier cold stage at 4 C | 0.70 | carousel |
| Bubble traps, tubing, inline flow and pressure sensors | 0.30 | inline |
| LumaScope-class inverted microscope (brightfield + 2 fluorescence channels) on a chip-scanning stage | 1.40 | microscope |
| Payload controller, pump drivers and harness | 0.50 | avionics, harness |
| Extra spill liner and insulation inside the BSL-2 containment | 0.30 | shell |
Every part with mass (85)
| Part | Role | kg | Size mm |
|---|---|---|---|
| Peltier cold stage (4 C) | store | 0.245 | 80 x 80 x 12 |
| carousel, 24 effluent tubes | store | 0.245 | 90 x 90 x 18 |
| effluent tubes | store | 0.070 | 77 x 77 x 16 |
| carousel drive | store | 0.105 | 20 x 20 x 20 |
| dispensing needle | store | 0.035 | 2 x 2 x 16 |
| controller enclosure (boards, data storage) | electronics | 0.360 | 140 x 93 x 28 |
| connector 1 | electronics | 0.020 | 12 x 8 x 12 |
| connector 2 | electronics | 0.020 | 12 x 8 x 12 |
| fluid manifold | pump | 0.360 | 50 x 146 x 12 |
| micro-pump 1 | pump | 0.150 | 20 x 20 x 26 |
| micro-pump 2 | pump | 0.150 | 20 x 20 x 26 |
| micro-pump 3 | pump | 0.150 | 20 x 20 x 26 |
| micro-pump 4 | pump | 0.150 | 20 x 20 x 26 |
| valve 1 | pump | 0.060 | 9 x 9 x 16 |
| valve 2 | pump | 0.060 | 9 x 9 x 16 |
| valve 3 | pump | 0.060 | 9 x 9 x 16 |
| valve 4 | pump | 0.060 | 9 x 9 x 16 |
| sensor bracket | fluid | 0.060 | 80 x 30 x 3 |
| bubble trap 1 | fluid | 0.060 | 16 x 16 x 25 |
| inline flow sensor | fluid | 0.060 | 22 x 16 x 14 |
| bubble trap 2 | fluid | 0.060 | 16 x 16 x 25 |
| inline pressure sensor | fluid | 0.060 | 22 x 16 x 14 |
| microscope base: optics, filter cubes, camera | imaging | 0.724 | 170 x 120 x 70 |
| objective | imaging | 0.046 | 22 x 22 x 16 |
| XY stage frame (travel 96.5 x 57.9 mm: every well over the objective) | imaging | 0.189 | 232 x 151 x 8 |
| stage carriage | imaging | 0.084 | 140 x 98 x 5 |
| X stepper | imaging | 0.073 | 28 x 20 x 20 |
| Y stepper | imaging | 0.073 | 20 x 16 x 20 |
| illumination column | imaging | 0.063 | 16 x 16 x 66 |
| illumination arm | imaging | 0.042 | 112 x 16 x 12 |
| LED head, transmitted light | imaging | 0.105 | 28 x 28 x 22 |
| SBS-format chip holder with fluidic manifold | sample | 0.240 | 128 x 86 x 8 |
| organ-chip 1 (slide format, 75 x 25 mm) | sample | 0.078 | 25 x 75 x 8 |
| organ-chip 1 channel with cells | sample | 0.006 | 2 x 60 x 2 |
| organ-chip 2 (slide format, 75 x 25 mm) | sample | 0.078 | 25 x 75 x 8 |
| organ-chip 2 channel with cells | sample | 0.006 | 2 x 60 x 2 |
| organ-chip 3 (slide format, 75 x 25 mm) | sample | 0.078 | 25 x 75 x 8 |
| organ-chip 3 channel with cells | sample | 0.006 | 2 x 60 x 2 |
| organ-chip 4 (slide format, 75 x 25 mm) | sample | 0.078 | 25 x 75 x 8 |
| organ-chip 4 channel with cells | sample | 0.006 | 2 x 60 x 2 |
| chip manifold port 1 | sample | 0.012 | 6 x 7 x 6 |
| chip manifold port 2 | sample | 0.012 | 6 x 7 x 6 |
| medium (120 mL) | fluid | 0.147 | 67 x 101 x 22 |
| medium port | fluid | 0.013 | 5 x 8 x 5 |
| drug (120 mL) | fluid | 0.147 | 67 x 101 x 22 |
| drug port | fluid | 0.013 | 5 x 8 x 5 |
| vehicle (120 mL) | fluid | 0.147 | 67 x 101 x 22 |
| vehicle port | fluid | 0.013 | 5 x 8 x 5 |
| fixative (120 mL) | fluid | 0.147 | 67 x 101 x 22 |
| fixative port | fluid | 0.013 | 5 x 8 x 5 |
| RNA-stabilising reagent (120 mL) | fluid | 0.147 | 67 x 101 x 22 |
| RNA-stabilising reagent port | fluid | 0.013 | 5 x 8 x 5 |
| bottom panel | housing | 0.023 | 313 x 191 x 2 |
| top panel | housing | 0.023 | 313 x 191 x 2 |
| side panel L | housing | 0.027 | 2 x 191 x 362 |
| side panel R | housing | 0.027 | 2 x 191 x 362 |
| back panel (bay interface) | housing | 0.044 | 310 x 2 x 362 |
| front panel | housing | 0.044 | 310 x 2 x 362 |
| corner post 1 | housing | 0.008 | 8 x 8 x 362 |
| corner post 2 | housing | 0.008 | 8 x 8 x 362 |
| corner post 3 | housing | 0.008 | 8 x 8 x 362 |
| corner post 4 | housing | 0.008 | 8 x 8 x 362 |
| shelf 1 | housing | 0.029 | 310 x 158 x 2 |
| shelf 2 | housing | 0.029 | 310 x 158 x 2 |
| cold wall (to the bay's thermoelectric block) | thermal | 0.011 | 290 x 4 x 207 |
| blind-mate connector: power, data, video | interface | 0.006 | 50 x 10 x 22 |
| grapple fixture base (Dexter-L) | interface | 0.006 | 70 x 4 x 70 |
| harness: controller and data storage to imaging stack: inverted microscope run 1 | harness | 0.001 | 5 x 6 x 5 |
| harness: controller and data storage to imaging stack: inverted microscope run 2 | harness | 0.002 | 5 x 20 x 5 |
| harness: controller and data storage to imaging stack: inverted microscope run 3 | harness | 0.007 | 5 x 5 x 81 |
| harness: controller and data storage to imaging stack: inverted microscope run 4 | harness | 0.006 | 68 x 5 x 5 |
| harness: controller and data storage to imaging stack: inverted microscope run 5 | harness | 0.003 | 5 x 38 x 5 |
| harness: controller and data storage to imaging stack: inverted microscope run 6 | harness | 0.001 | 5 x 6 x 5 |
| harness: controller and data storage to 4 micro-pumps run 1 | harness | 0.001 | 5 x 6 x 5 |
| harness: controller and data storage to 4 micro-pumps run 2 | harness | 0.002 | 5 x 20 x 5 |
| harness: controller and data storage to 4 micro-pumps run 3 | harness | 0.004 | 5 x 5 x 41 |
| harness: controller and data storage to 4 micro-pumps run 4 | harness | 0.015 | 173 x 5 x 5 |
| harness: controller and data storage to 4 micro-pumps run 5 | harness | 0.009 | 5 x 104 x 5 |
| harness: controller and data storage to 4 micro-pumps run 6 | harness | 0.004 | 5 x 5 x 39 |
| harness: controller and data storage to 4 micro-pumps run 7 | harness | 0.001 | 5 x 5 x 6 |
| harness: controller to the connector run 1 | harness | 0.002 | 5 x 5 x 24 |
| harness: controller to the connector run 2 | harness | 0.009 | 5 x 98 x 5 |
| harness: controller to the connector run 3 | harness | 0.017 | 189 x 5 x 5 |
| harness: controller to the connector run 4 | harness | 0.017 | 5 x 5 x 189 |
| harness: controller to the connector run 5 | harness | 0.001 | 5 x 8 x 5 |
Measured in orbit
- Tissue shape and cell coverage in the channel Brightfield images from the bay microscope (LumaScope-class) through the clear chip
- Live reporter signals (e.g. cell-death or stress dyes, or GFP lines) Two-channel fluorescence imaging on the bay microscope. The arm can move a bay to the central 40x microscope for close-ups (not during sensitive steps).
- Flow, line pressure and bubble or blockage events Pump telemetry plus inline flow and pressure sensors on each chip line
- Beat rate, force and rhythm (heart-chip variant only) Time-lapse video from the microscope, or magnet-in-post with magnetic sensors as on the ISS heart platform. This must be added; it is not a standard bay service.
- Environment log Bay temperature, pressure, humidity, acceleration and radiation dose (silicon dosimeter and TLDs) logged for every chip
Measured after the return
- Injury and inflammation biomarkers in effluent (e.g. KIM-1, IL-6, LDH) ELISA or multiplex immunoassay on each time-stamped effluent fraction
- Drug and metabolite levels in effluent (e.g. vitamin D metabolites) LC-MS/MS
- Whole-transcriptome changes RNA-seq on chips held in RNA-stabilising reagent, compared with matched ground chips
- Tissue structure, junction and transporter proteins Immunofluorescence and confocal microscopy of fixed chips
- Mitochondrial and sarcomere ultrastructure Transmission electron microscopy of fixed chips
Ground control
Chips from the same cell lot and seeding batch run in an identical flight-spare bay on the ground, with the same pumps, reservoirs, flow rates, imaging schedule, dosing time and fixation time. The ground run follows the flight about 2 h behind, driven by the flight telemetry, and replays the recorded flight temperatures and 4 C hold durations. Where possible it also gets a launch-vibration profile and the same pre-launch storage time, so microgravity is the main difference. Extra chips stay in a standard CO2 incubator as a baseline for the hardware itself.
Coming home
Our estimate, not a source value. All chips are fixed or RNA-stabilised in orbit and effluent is collected at 4 C, so nothing needs to stay alive through return. The chain is held at 4 C: about 1 day in orbit after fixation, re-entry, about 20 min to the recovery ship, then 1-2 days to the lab. The ISS heart study stored PFA-fixed samples at 4 C, which matches this plan. But both ISS studies kept RNAlater samples or vitamin D effluent at -80 C, which LELP-1 cannot do. Customers must test RNA quality and labile markers after a 4 C hold of the same length on the ground, and the ground control must use the same hold times.
Limits of this flight
- Short exposure: LELP-1 runs at most 14 days. The ISS heart study ran about 30 days. The ISS kidney study found no unique response after 6 days plus 2 days of treatment, and the authors call for study of longer exposure. Slow effects may not show up in a LELP-1 flight.
- No crew: nobody can clear a bubble, re-prime a line or swap a leaking or contaminated chip. A failed chip is lost, so each condition needs at least two chips.
- Live launch: mature organ-chips are launched live, so they must survive late loading, any launch slip and ascent at 37 C. BioSentinel lost its yeast to long pre-launch storage, and EcAMSat cells were stressed by multi-week storage, so launch-slip limits must be agreed with the customer.
- No -80 C freezing in orbit: samples are fixed or RNA-stabilised and returned at 4 C. Both ISS chip studies froze some samples at -80 C. Markers that need frozen samples may degrade.
- No CO2 or incubator gas control: the ISS heart tissues were kept at 5% CO2, but LELP-1 media must be HEPES-buffered and oxygen depends on gas-permeable chip materials. The customer must qualify the chip and medium in a sealed, CO2-free bay on the ground first. Some chip plastics (e.g. PDMS) may absorb small hydrophobic drugs, so the drug must also be qualified on the same chips.
- No in-flight 1 g control: LELP-1 has no centrifuge, so the 1 g comparison is only on the ground, and launch, re-entry and radiation effects are mixed in with the microgravity effect.
- Few chips per bay (about 4-6) and microlitre effluent volumes limit how many doses and assays one bay supports. Big dose-response studies need several bays.
- Microgravity at the bay is good (about 1e-6 g) but drops to about 1e-4 to 1e-3 g while the arm moves, so arm moves must be scheduled away from key steps.
- The protocol and module here are a reference design in a digital twin. LELP-1 has not flown yet, and none of the heritage results above were obtained on LELP-1.
A satellite of its own: SP-CHIP B · samples return, hardware burns up
SP-CHIP is a 122 kg free-flyer. Only the samples come home: 2.4 kg ride in a 45 kg capsule in a drawer behind an optical window; the microscope looks through the window from the service module, and fluid lines cross through dry-break couplings that part at separation once the last fluid step is done. The microscope, pumps and reservoirs stay in the service module and burn up with it. Why B: chips are fixed in orbit; the effluent carousel needs power and a heat path through entry and the hold.
Comes home · capsule
| organ-chips with holders and manifold | 0.60 |
| effluent-collection carousel with its Peltier stage | 0.70 |
| sample drawer, optical window, dry-break couplings | 0.50 |
| drawer thermoelectric block | 0.60 |
| Capsule at entry (with heat shield, parachute, hold battery, margin) | 45.0 |
Stays · service module
| experiment instruments, pumps and reservoirs | 4.50 |
| Service module dry, with power, radios, attitude, propulsion | 66.0 |
Budgets · estimate
| Launch mass | 121.5 kg |
| Propellant for 190 m/s | 10.5 kg |
| Average / peak load | 67 / 113 W |
| Array, worst eclipse season | 145 W |
| Battery (sized by ascent) | 241 Wh |
| Deorbit burn | 2 × 22 N, 525 s |
Tailored for this experiment
- A second, cold zone at 4 C for effluent inside a bay held at 37 C. The standard bay has one setpoint, so the module brings its own small Peltier stage, and the bay must take its heat.
- Late loading of live chips (within about 24 h of launch) and bay power and heating from loading through ascent. Live chips cannot launch in the -80 C passive cassette.
- Sterile assembly, leak checks and contamination screening before loading (the ISS kidney study lost about a third of flight samples to mold)
- Inline flow and pressure sensing and bubble traps on every chip line, with telemetry, so the ground can see blockages or bubbles
- A chip-scanning stage under the bay microscope (or arm transfers to the 40x central microscope) to image several chips
Bay or satellite?
The capsule is the floor: no capsule much smaller than about 45 kg has been recovered yet, so 2.4 kg of samples need 122 kg of satellite. On LELP-1 the same samples share one capsule, the whole lab, with 31 other bays. A dedicated satellite earns its place when the experiment needs the schedule to itself, a quieter ride (about 7.3 × 10⁻⁸ g quasi-steady, no robotic arm), or power a bay cannot give.
First-order sizing with a 20 % margin by one model for every experiment, reviewed independently; caveats and sources. The smallest recovered capsule so far (Varda W-1) is under 90 kg, so treat these masses as optimistic.
References
- NIH National Center for Advancing Translational Sciences (NCATS). Tissue Chips in Space (programme page). NCATS, NIH. https://ncats.nih.gov/research/research-activities/tissue-chip/projects/space
- Lidberg KA, et al., Kelly EJ (2024). Modeling cellular responses to serum and vitamin D in microgravity using a human kidney microphysiological system. npj Microgravity 10:75. doi:10.1038/s41526-024-00415-2 https://doi.org/10.1038/s41526-024-00415-2
- Mair DB, et al., Kim DH (2024). Spaceflight-induced contractile and mitochondrial dysfunction in an automated heart-on-a-chip platform. PNAS 121(40):e2404644121. doi:10.1073/pnas.2404644121 https://doi.org/10.1073/pnas.2404644121
- Ricco AJ, Parra M, Niesel D, et al. (2011). PharmaSat: drug dose response in microgravity from a free-flying integrated biofluidic/optical culture-and-analysis satellite. Proc. SPIE, Microfluidics, BioMEMS, and Medical Microsystems IX. doi:10.1117/12.881082 https://researchexperts.utmb.edu/en/publications/pharmasat-drug-dose-response-in-microgravity-from-a-free-flying-i/
- Padgen MR, et al., Matin AC (2020). EcAMSat spaceflight measurements of the role of sigma-s in antibiotic resistance of stationary phase Escherichia coli in microgravity. Life Sciences in Space Research 24:18-24. doi:10.1016/j.lssr.2019.10.007 https://doi.org/10.1016/j.lssr.2019.10.007
- Santa Maria SR, Zea L, Ricco T (2019). Biological CubeSats: What Have We Learned so Far and What Is Next? ASGSR Annual Meeting, Denver. NASA Technical Reports Server 20190033204. https://ntrs.nasa.gov/citations/20190033204
- NASA Ames Research Center. BioSentinel (mission page). NASA. https://www.nasa.gov/ames/biosentinel
Fact-check: 18 claims and sources checked, 6 confirmed, 11 corrected, 1 removed · confidence high